| Model: TR-5
Automatic / Manual Fan Speed Curve Control
High 5.25” LCD Display
4 sets of Fan Speed Detection
4 sets of Temperature Detection
Alarm for fan Error / Over temperature
Icon shows Power On/ HDD access on LCD | |
|
 |
 |
|
 |
 |
 |
 |
 |
Features
Specifications
TR-5 Function Instruction
1. Temperature/ Fan Speed Display:
a. Press C key to switch between four different fan speed/ temperature
displays. The switch order is as follows: Fan1?Fan 2?Fan 3?Fan 4 For
corresponding fans; CPU?VGA?SYS1?SYS2 for corresponding temperature
sensors reading.
Note: Temperature range: 0? to 99?. Accuracy: +/-2?.
b. To switch between ? and ? temperature display modes with A key.
2. Fan Speed/ Temperature Alarm/ Date / Time Setting
By Press B key for 3 seconds, after the beep sound, you will be enter
the setting mode, you can press B key to switch to different functions
in order, Fan 1to 4, Temperature Alarm CPU to SYS2, date, and time.
And only using A key to adjust the setting
a. Fan Speed adjustment:
As factory setting , all settings set to automatic, the fan speed will
be automatically adjusted when temperature changes. ( Fan 1 – CPU /Fan
2 – VGA/ FAN3 – SYS1/ Fan4 –SYS2). To adjust the fan speed manually,
hold the B key for 3 seconds, and after the beep sound, using A key to
change the speed setting. There are 6 modes; S-A (Automatic)to S-L (Low
Speed)to S-1 to S-2 to S-3 to S-H (High Speed)
Note: when fan fail, the buzzer will start beeping, and the display
backlight will turn into red, and start flashing until the faulty has
been removed. If the fan failed before the system power on, the TR-5
won’t be able to detect the fail fan.
b. Temperature Alarm Adjustment:
As Factory Setting, temperature alarm setting as CPU : 70°C/158°C; VGA: 60°C/140°C; SYS1&2: 50°C/122°C
The adjustment range from 40°C/104°C to 70°C/194°C. When the reading is
over the limit, the buzzer will start beeping, and the display
backlight will turn into red, and start flashing until the faulty has
been removed.
Only Use DC 12V 0.45Amax 3pin fan.
c. Time Adjustment:
24-hour time display and perpetual calendar functions
a. Year adjustment: press B key?click B key 9 times until the characters of the year start flashing?press A key to adjust
b. Month adjustment: press B key?click B key 10 times until the characters of the month start flashing?press A key to adjust
c. Date adjustment: press B key?click B key 11 times until the characters of the date start flashing?press A key to adjust
d. Hour adjustment: press B key?click B key 12 times until the characters of the date start flashing?press A key to adjust
e. Minute adjustment: press B key?click B key 13 times until the characters of the date start flashing?press A key to adjust
3. The module comprises “HDD” status indication function of the
main board. HDD symbol will rotate while receiving the reading signal
of the HDD.
4. RESET
Press D key to reset to default settings |
|
|
 |
 |
 |
 |
|
 |

|